Skip to product information
1 of 1

ActronAir Classic Fixed Speed Split Ducted System 1 Phase CRA170S / EVA170S 16.8kW | NEO Touch Master Controller Packaged

ActronAir Classic Fixed Speed Split Ducted System 1 Phase CRA170S / EVA170S 16.8kW | NEO Touch Master Controller Packaged

Regular price $7,045.00 AUD
Regular price Sale price $7,045.00 AUD
Sale Sold out

FREE PICKUP ACROSS AUSTRALIA! Contact us now for details

CRA170S: Outdoor Single Phase

EVA170S:  Indoor Includes 8 Zones integrated and 20m data cable for controller

NTB-1000/NTW-1000 : NEO TOUCH Master Wall Controller

Specifications:



Indoor Model CRA170S
Outdoor Model EVA170S
Total (Gross) Capacity (kW)

 

(AS/NZS3823.1.2)

Cooling (Rated) 17.38
Heating (Rated) 17.02
Net (Rated) Capacity (kW)

 

(AS/NZS3823.1.2)

Cooling 16.80
Heating 17.57
Input Power (kW)

 

(AS/NZS3823.1.2)

Cooling 5.15
Heating 4.76
2 EER Rated (AS/NZS3823.1.2)

 

3 COP Rated (AS/NZS3823.1.2)

Cooling 3.26
Heating 3.69
Power Supply (V / Ph / Hz) Outdoor 230V / 1Ph + N / 50Hz
Indoor 230V / 1Ph + N / 50Hz
Rated Load Amps (AS/NZS3823.1.2)

 

Full Load Amps (AS/NZS3823.1.2)

Outdoor/ Indoor / Total 19.7 / 4.3 / 24.0
Outdoor / Indoor / Total 30.7 / 4.3 / 35.0
4 Circuit Breaker Amps 40.0
IP Rating Outdoor IP44
Indoor IP22
Compressor Type / No. per Unit Compliant Scroll / 1
Starting Method Soft Starter
No. Refrigeration Circuits/No. Capacity Stages (Capacity range) 1/1 (100% capacity)
Refrigerant R410A
Fans (Type x Number per unit) Outdoor Axial / 6 Pole External Rotor / Direct Drive x 2
Indoor Twin Deck Centrifugal / ECM Direct Drive x 1
Airflow Range Indoor (l/s) Maximum 900
Nominal 850
Minimum 770
External Static Pressure (Pa) at: Maximum Airflow 116
Nominal Airflow 164
Outdoor Dimensions (mm) Depth 580
Height 1045
Width 1460
Indoor Dimensions (mm) Depth 615
Height 412
Width 1290
Nominal Weight (kgs) Outdoor 156
Indoor 56
Field Pipe Size Liquid Pipe – mm (inch) 9.52 (3/8)
Gas Pipe – mm (inch) 19.05 (3/4)
Sound Pressure Level (dBA)

 

Sound Power Level (dBA)

Outdoor (low / med / high fan) 50.4 / 51.3 / 53.1
Outdoor (low / med / high fan) 69.8 / 70.7 / 73.1
MEPS Compliant Yes Yes
Demand Response Capability (AS4755.3) Capable Capable
8-Zone Capability Standard Standard
View full details

Contact form