Skip to product information
1 of 2

FUJITSU SET-ARTA45LATU 11.5kW Inverter Ducted System Slimline 1 Phase

FUJITSU SET-ARTA45LATU 11.5kW Inverter Ducted System Slimline 1 Phase

Regular price $4,344.00 AUD
Regular price Sale price $4,344.00 AUD
Sale Sold out

FREE PICKUP ACROSS AUSTRALIA! Contact us now for details

11.5kW Cool – 14.0kW Heat / Indoor ARTA45LATU – Outdoor AOTA45LCTL.Inverter Ducted Slim Design

Wired Back lit Controller : UTY-RVNYN

Automatic Air Flow Adjustment

When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.

Program Timer

This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.

Control Port

External inputs and outputs contained within the product allow on/off control, fresh air interlock connection and heater bank element connection. UTD-ECS5A* (optional parts). * Selected ducted units only.

ALL DC

With All DC, electricity loss is decreased and power consumption reduced.

Auto-Changeover

The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.

Fresh air intake

Fresh air can be taken in by a fan which can be connected using UTD-ECS5A* (optional parts). *Selected ducted units only

Weekly Timer

Different on-off times can be set for up to 7 days.

Auto Restart

Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.

Economy mode

Limits the maximum operation current, and performs operation with the power consumption suppressed.

ON-OFF Timer

ON-OFF timer can be set to operate once every 24 hours.

Blue Fin Heat Exchanger

Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchange.

Connectable Distributing Duct

Conditioned air can be distributed to adjacent areas by means of a distribution duct.

Specifications:
Model No. – Indoor ARTA45LATU
Model No. – Outdoor AOTA45LCTL
Reverse Cycle System Yes
Capacity Class
Cooling Capacity (Watts) 11,500
Cooling Capacity (BTU/h) 39,300
Range (Watts) 4,000 – 13,300
Range (BTU/h) 13,700 – 45,400
Heating Capacity (Watts) 14,000
Heating Capacity (BTU/h) 47,800
Range (Watts) 4,200 – 15,500
Range (BTU/h) 14,300 – 52,900
Power Supply (Volts) 240
Phase-Frequency (Ph – Hz) 1 – 50
Power Supply Attachment Outdoor
Plug Size (If Applicable) N/A
Running Current, Cooling (Amps) 14.9
Running Current, Range (Amps) Max: 21.0
Input, Cooling (Watts) 3,560
Input, Range (Watts) Max: 5,020
Running Current, Heating (Amps) 16.8
Running Current, Range (Amps) Max: 21.0
Input, Heating (Watts) 4,020
Input, Range (Watts) Max 5,020
Input (Watts)
Moisture Removal (l/hr) 4
E.E.R. – Cooling 3.23
C.O.P. – Heating 3.48
Star Rating – Cooling
Star Rating – Heating
Fan Speed 4
Air Circulation, High (l/s) 583
Compressor Type DC Rotary
Dimensions – Inside Unit (HxWxD mm) 270 x 1,135 x 700
Weight – Inside Unit (kg) 40
Dimensions – Outside Unit (HxWxD mm) 1,290 x 900 x 330
Weight – Outside Unit (kg) 86
I.U. Sound Pressure Level (dBA@1mtr) 42
O.U. Sound Pressure Level (dBA@1mtr) 55
O.U. Sound Power Level (dBA) 69
Refrigerant Type R410A
Connection Pipe Sizes, Gas (mm) 15.88
Connection Pipe Sizes, Liquid (mm) 9.52
Pre Charged Length (Metre) 20
Minimum Pipe Length (Metre) 5
Maximum Pipe Length (Metre) 50
Maximum Pipe Height (Metre) 30
Pipe Connection Methods Flare
Outdoor operating Temp, Cooling Degrees C -15 to 46
Outdoor operating Temp, Heating Degrees C -15 to 24