FUJITSU SET-ARTH18KLLAP 5kW Inverter Bulkhead Ducted System
FUJITSU SET-ARTH18KLLAP 5kW Inverter Bulkhead Ducted System
FREE PICKUP ACROSS AUSTRALIA! Contact us now for details
FUJITSU SET-ARTH18KLLAP 5kW Inverter Bulkhead Ducted System
Features a compact design to allow for flexible installation in the best available space.
- Features a compact design to allow for flexible installation in the best available space.
-
All DCWith All DC, electricity loss is decreased and power consumption reduced.
-
Auto RestartShould there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.
-
Auto ChangeoverThe unit automatically switches between operating modes based on the temperature setting and room temperature.
-
Blue Fin Heat ExchangerCorrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.
-
Connectable Distributing DuctSystems are capable of attaching a field-supplied branch ducts distributing the airflow.
-
Economy ModeLimits the maximum operation current, and performs operation with the power consumption suppressed.
-
On-Off TimerON-OFF timer can be set to operate once every 24 hours.
-
Weekly + Setback TimerWeekly + setback timer can set temperature for two-time spans and for each day of the week.
-
Error Code Display
Specifications:
Operation Type Reverse Cycle Power Source V/Ph/Hz 240 / 1 / 50 Cooling Capacity kW (Rated (Min – Max)) 5.00 (0.9 – 5.9) Heating Capacity kW (Rated (Min – Max)) 6.00 (0.9 – 7.5) Input Power Cooling kW (Rated (Max)) 1.38 (2) Input Power Heating kW (Rated (Max)) 1.6 (2.39) EER Cooling kW/kW 3.62 COP Heating kW/kW 3.75 Star Rating Cooling (0-10) (Hot / Average / Cold) 3 / 3 / 3 Star Rating Heating (0-10) (Hot / Average / Cold) 3 / 2.5 / 2 Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.868 / 4.508 / 4.656 Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.661 / 4.105 / 3.536 Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 5.216 / 5.295 / 5.644 Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.667 / 4.33 / 3.843 Running Current amps (Cooling / Heating) 5.9 / 6.8 Moisture Removal l/hr 2 Indoor Sound Pressure Cooling dBA (High / Quiet) 32 / 27 Indoor Sound Pressure Heating dBA (High / Quiet) 32 / 27 Outdoor Sound Pressure dBA (Cooling / Heating) 48 / 49 Outdoor Sound Power dBA 62 Air Circulation (Indoor – High Fan) Cooling l/sec 261 Air Circulation (Indoor – High Fan) Heating l/sec 261 Indoor Unit Dimensions mm (Height x Width x Depth) 198 x 900 x 620 Indoor Unit Weight kg 20.00 Outdoor Unit Dimensions mm (Height x Width x Depth) 632 x 799 x 290 Outdoor Unit Weight kg 36.00 Piping Connects mm Ø (Liquid / Gas) 6.35 / 12.7 Pipe Length m (Max (Precharged)) 30 (20) Max Height Difference m 20 Operation Range Cooling °CDB (Min to Max) -10 to 46 Operation Range Heating °CDB (Min to Max) -15 to 24 Refrigerant Type R32 Refrigerant Amount g 1,020